24-Port 10/100/1000Mbps with 16-Port SFP Web Smart Ethernet Switch GSW-2416SF User’s Manual - 1 -
3.2.2 Web Management You can manage the GSW-2416SF remotely by having a remote host with wUsing this management method: The GSW (IP) address accessibl
3.4 Logging on to the GSW-2416SF for a word. When you log on to the GSW-2416SF console port for the first time, a sign-on string appears and you are
4. CONSOLE INTERFACE 4.1 CONNECT TO PC RS-232 serial cable Use the bundled RS-232 serial cable and attach the 9-pin female connector to the ma
4.2 Login in Login is required to access the console interface after the self-test completes successfully. The factory default user name is "admi
4.4 Getting Started >” prompt. The screen of available commands in Figure 4-4 appears, and the detail description shown in Table 4-1. 4.4.1 General
set flowcontrol [n] enable/disable Enable/Disable the flow control function to specific port [n] of GSW-2416SF. set vlantag [n] enable/disable Enable/
sho se refer to chapter 4.4.2.6w flowcontrol : Plea . sho e refer to chw vlantag : Pleasapter 4.4.2.7. sho ease refer to w vlanaware : Plchapter 4.
Figure 4-7 Per port static screen #Notice: The TX/RX packets counted with error might because: z Packet with a bad FCS. z Packets were less than
4.4.2.4 Show ip Display the current IP address, netmask and gateway of GSW-2416SF. The IP subnet address information screen in Figure 4-9 appears. F
4.4.2.6 Show flowcontrol of Enabled – 802.3x flow control is enabled on Full-Duplex mode or Backpressure is enabled on Half-Duplex mode.. Disabled –
Trademarks Copyright © PLANET Technology Corp. 2006. Contents subject to revision without prior notice. PLANET is a registered trademark of PLANET Tec
4.4.2.8 Show vlanaware Display current VLAN-aware status on each port of GSW-2416SF. Enabled – Tagged Frame remain original VID while leaving tagged p
4.4.2.10 Show pvid Display the current per port PVID of GSW-2416SF. The Allowed PVID values are form 0-4095. The per port PVID display screen in Figu
4.4.3 Set command From the main menu screen (see Figure 4-3), input “set” and press enter. The set command list screen in Figure 4-17 appears.
4.4.3.1 Set port [n] This command allows configuring per port parameters of GSW-2416SF. the correct usage is shown as below: Set port [n]: n=1-24, to
Figure 4-19 VLAN members Configuration screen #Notice: Change VLAN settings for every time, you have to reboot the switch to apply new settings. 4.
4.4.3.4 Set vlantag This is an additional function of VLAN configuration. This command allows configuring per port VLAN Tagged/Untagged status. When a
Figure 4-22 VLAN aware Configuration screen #Notice: Change VLAN settings for every time, you h
4.4.3.7 Set pvid This is an additional function of VLAN configuration. This command allows assign PVID for selected port of GSW-2416SF. The correct us
Figure 4-25 VID Configuration screen #Notice: Change VLAN settings for every time, you have to reboot the switch to apply new settings. 4.4.3.9 Se
Figure reen ass w: set pass [oldpass] [newpass] se the new password. 4-26 IP subnet address configuration sc4.4.3.10 Set pThis command allows ass
TABLE OF CONTENTS 1. INTRODUCTION ...
4.4.4 Factory default This command allows rest GSW-2416SF to factory default mode. The factory default screen in Figure 4-28 & 4-29 appears. Fig
4.4.5 Reboot This command allows reboot GSW-2416SF, the reboot screen in Figure 4-30 & 4-31 appears. Figure 4-30 Switch reboot screen Figure 4-3
4.4.6 Logout This command provides logout the GSW-2416SF, the screen in Figure 4-32 appears. Fig en ure 4-32 GSW-2416SF Logout screEM-GSW2416SFv1 -
4.5 Firmware Update This section will show you how to use X-modem to update the firmware of GSW-2416SF. Firmware update requirements GSW-2416SF swit
Figure 4-34 Firmware Update Figure 4-35 Xmodem transmit After the file send be completed, the system will reboot automatically to the login scree
5. WEB MANAGEMENT Before login the Web interface of GSW-2416SF, please setup the “IP Address” with local serial console port (RS232 port) and use this
5.2 Port Config This section provides current ports status and detail setting of each port of GSW-2416SF. The screen in Figure 5-3 appears and Table 5
Object Description Port Indicate port 1 to port 24. Mode Allow configuring the port speed and operation mode. Draw the menu bar to select the mode. z
5. SetupA V LAN (VLAN) ng that limits the broadcast domain. It allows you to isolate network traffic so only VLAN members. Basically, creating a VLAN
5.3.2 VLAN setting example: -5 appears and Table 5-2 describes the port configuration of switch. 5.3.2.1 Two separate VLAN The diagram shows how the
1. INTRODUCTION 1.1 Checklist Check the contents of your package for following parts: z GSW-2416SF x1 z User's manual CD x1 z Quick installa
Setup steps 1. VLAN Group Set VALN Group 1 = default-VLAN with VID (VLAN ID)=1 2. Assign VLAN Member : VLAN 2: Port-1, Port-2 and Port-3 VLAN 3: Por
Figure 5-7 VLAN 1 member assign Web page screen Figure 5-8 VLAN 2 member assign Web page screen EM-GSW2416SFv1 - 41 -
Figure 5-9 VLAN 2 member assign Web page screen #Notice: Change VLAN settings for every time, you have to reboot the switch to apply new settings.
5.4 Port Trunk Setup This section allows you to disable or enable trunk function of two ports or four ports together to speed up data transmission. Th
#Notice: 1. After turn on the port trunk feature, port 1 and port 2 or port 17,18,19,20 should connect to another switch, hole 2. The GSW-2416SF does
5.5 Status Thconnection info. The screen in Figure 5-12 appears. 5.5.1 Port Status is section displayed the current link status of each port on GSW-2
Figure 5-13 GSW-2416SF Port Statistics Web Page screen There’re also two buttons at the statistics web page – “Clear” and “Refresh”. Press the “Clea
5.6 Misc Configuration This section provides Misc Configuration of GSW-2416SF. 5.6.1 System Setup This section provides System Configuration of GSW-2
5.7 Tools This section provides two management tools of GSW-2416SF- Reboot and Factory Reset. mmediately. After system reboot, the manager has to refr
5.7.2 Factory Reset g configuration: z Default IP address: 192.168.0.100 t mask: 255.255.255.0 After choose this function and the following screen ap
◆ Support CSMA/CD protocol ◆ 100~240VAC, 50~60Hz universal Power input ◆ FCC, CE class A compliant 1.4 Specification Model GSW-2416SF 10/100/1000B
5.8 Logout This section allows to logout the GSW-2416SF. Press “Logout” item in the Web Menu, it take effect immediately. If the manager wa ” button.
6. SWITCH OPERATION 6.1 Address Table The Switch is implemented with an address table. This address table composed of many entries. Each entry is used
7.TROUBLESHOOTING This chapter contains information to help you solve problems. If the Switch is not functioning properly, make sure the according to
APPENDIX A NETWORKING CONNECTION A.1 Switch‘s RJ-45 Pin Assignments 10/100Base-TX Contact MDI MDI-X 1 1 (TX +) 3 2 2 (TX -) 6 3 3 (RX +) 1 6
Figure A-1: Straigh and Crossover Cable s are with same pin assignment and color as above picture before deploying the t-ThroughPlease make sure
2. HARDWARE DESCRIPTION This product provides both Copper and Fiber connecter at same switch – 24 Ports TP and 16 Ports SFP (shared with Port #9 to 2
Power Notice: 1. The device is a power-required device, it means, it will not work till it is powered. If your networks should active all the ti
Caution: You must use the screws supplied with the mounting brackets. Damage caused to the parts by using incorrect screws uld invalidate your warran
3. SWITCH MANAGEMENT anage the GSW-2416SF. Topics include: - Log 3.1 Overview This chapter gives an overview of switch management. The GSW-2416SF p
Kommentare zu diesen Handbüchern